Ul 555 standard for fire dampers meaning
WebFor maximum safety in all situations, the fire and smoke actuators meet all codes for commercial buildings in the U.S., pass UL 555 and UL 555S at 177ºC and are tested for 30,000 open-closed cycles with approved dampers. Belimo fire and smoke damper actuators exceed UL’s requirement of 20,000 cycles at damper static load. WebANSI/ UL 555, Standard for Safety Fire Dampers, 2006, Revised 2012 201 4.ANSI/ UL 555C, Standard for Safety Ceiling Dampers, 2006, Revised 2010 2014. ANSI/ UL 555S, Standard for Safety Smoke Dampers, 1999, Revised 2012 2014. ANSI/ UL 723, Standard for Test for Surface Burning Characteristics of Building Materials, 2008, Revised
Ul 555 standard for fire dampers meaning
Did you know?
Web23 Oct 2024 · Ceiling dampers and ceiling air diffusers intended for use in HVAC systems where the airflow is operational at the time of a fire, such as in a smoke control system, or … Web9 Oct 2024 · UL 555 October 21, 2016 Standard for Fire Dampers 1 Scope 1.1 The fire dampers covered by these requirements are intended for installation in accordance with the National Fire Protection Association Standard for Installation of Air-Conditioning and... UL …
Web4 Dec 2024 · The UL 555C Standard is one of three standards that are actively maintained by the UL 555 Standards Technical Panel (STP). Like STPs for other product standards, … Web1.6 Combination fire and smoke dampers and corridor dampers shall also comply with the applicable requirements in the Standard for Smoke Dampers, UL 555S. 1.7 Fire dampers …
WebClass 1 dampers. UL Classified Leakage Ratings UL Standard 555S, Smoke Dampers, is the test standard to qualify dampers for use in smoke-control systems. UL 555S identifies leakage classes for both smoke and combination fire/smoke dampers (combination fire/smoke dampers must meet the requirements of both UL 555, Fire Dampers, and UL … Web1. UL 555 - Standard for Safety for Fire Dampers. 2. UL 555C - Standard for Safety for Ceiling Dampers. 3. UL 555S - Standard for Safety for Smoke Dampers. 1.3 SUBMITTALS A. Product Data: Submit data for shop fabricated assemblies and hardware used. B. Product Data: Submit for the following. Include where applicable electrical characteristics
WebReferenced Codes & Standards § IMC section 606 § IBC section 907 § UL 864 Standard for Control Units and Accessories for Fire Alarm Systems § UL 555 Standard for Fire Dampers § UL 555 S Standard for Smoke Dampers § UL 555 C Standard for Ceiling Dampers § UL 263 Standard for Fire Tests of Building and Construction Materials § NFPA 72 National …
Webaccordance with the latest version of UL 555/UL555S. As part of the UL standards, fire/smoke dampers shall have demonstrated a capacity to open and close under HVAC system operating conditions, with pressures up to 4 inches w.g. in the closed position and 2000 fpm air velocity In the open position. christian porter australiaWeb1.6 Combination fire and smoke dampers and corridor dampers shall also comply with the applicable requirements in the Standard for Smoke Dampers, UL 555S. 1.7 Fire dampers … christian porter latest newsWeb19 Aug 2014 · Fire, smoke, and combination fire and smoke dampers are used in two general categories: containment of fire and smoke and smoke control systems. ... UL 555 Standard for Safety for Fire Dampers, Edition 7, 2006, Updated 2010, Underwriters Laboratories Inc. (UL), 333 Pfingsten Road, Northbrook, IL 60062-2096. UL 555S Standard … georgia shorebird allianceWebConstructed from 2 mm frame and (1+1 mm) aerofoil blades with Steel bushes, bearings, shaft and linkage concealed in jamb seals with a sleeve of length 415 to 673 mm. Damper … georgia shooting suspect caughtWebIn line with UL555S, smoke dampers are designed to be a low leak damper that is usually motorized so it can be shut down and closed in the event of a fire and opened again if … georgia shopping centerWebwww.amca.org christian porter ministerWebThese dampers meet and exceed the stringent test criteria for both test standards. UL 555/555S-702/Replaces UL 555/555S-82000 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Ruskin 2002. 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955. christian porter minter ellison